Puddle flanges · puddle pipes · wall sleeves
Stop water at the wall.
Welded puddle flanges for every pipe that passes through concrete. Hot-dip galvanized, stainless steel or epoxy coated, from DN25 to DN1200, built to your wall thickness and delivered across the GCC.

Product selector
Build your puddle flange in six steps
Choose the application, material and size. The drawing and specification update as you go. Add each item to your list and send the whole enquiry to us on WhatsApp.
Dimensions and weight are indicative and exclude end flanges. Final dimensions are confirmed on the approval drawing sent with your quotation.
Your enquiry list
Product range
Eight ways we make a puddle flange
PF-HDGGI (hot-dip galvanized) puddle flange
Carbon steel puddle pipe galvanized after welding. The standard choice for basements, pump rooms and fire water tanks.
PF-MSMS (mild steel) puddle flange
Black or primed mild steel puddle pipe for dry services and for site painting.
PF-SS304Stainless steel 304L puddle flange
SS 304L puddle flange for clean water, process plants and indoor wet areas.
PF-SS316Stainless steel 316L puddle flange
SS 316L puddle flange for drinking water, sewage, pools, RO plants and coastal sites.
PF-EPXEpoxy coated puddle flange
Carbon steel puddle pipe with factory-applied epoxy for potable and fire water tanks.
PF-FLGFlanged puddle pipe
Puddle pipe with one or both ends flanged, drilled to EN 1092-1, ASME B16.5, BS 10 or AWWA C207.
PF-SPLSplit bolt-on puddle flange
Two-piece plate that clamps around a pipe already in place, for retrofit and site corrections.
PF-SLVWall sleeve with puddle flange
Cast-in sleeve with a puddle plate. The service pipe passes through later and is sealed with a link seal.
Applications
Where puddle flanges are used
USEWater tanks
Every inlet, outlet, overflow, drain and level sensor pipe through a concrete tank wall needs a puddle flange. Flanged…
USEBasements
Below ground walls sit in wet soil and often below the water table, so each service entry is a leak risk. Puddle…
USEPump rooms
Suction and delivery pipes pass between the tank and the pump room through a common wall. Flanged puddle pipes keep…
USESewage treatment plants
Treatment tanks hold corrosive liquid and gas. Penetrations between tanks, channels and galleries need a water stop…
USESwimming pools
Return inlets, suction lines, main drains and light conduits all pass through the pool shell. A leak here is expensive…
USEFire water tanks
Fire tanks need suction, fill, test return, overflow and drain connections through the wall. Flanged puddle pipes sized…
USEManholes and chambers
Pipes entering cast in-situ chambers need a water stop so ground water does not enter around the pipe. Split puddle…
USERO and process plants
Process buildings have many wet rooms, bunds and tanks with hygienic or corrosive duties. Stainless steel penetrations…
Sizes
Every size from 1 inch to 48 inch
Each size has its own page with dimensions, lengths and weights.
Guides
Technical guides
- What is a puddle flange?
- Puddle flange installation: step by step
- Puddle flange size chart and dimensions
- Puddle flange vs pipe sleeve: which one do you need?
- Puddle flange vs thrust flange
- How to choose puddle flange material
- Puddle flange standard detail for drawings
- GI vs stainless steel puddle flange
- Puddle flange weight calculation
- How to order puddle flanges: BOQ wording
Questions
Puddle flange basics
What is a puddle flange?
A puddle flange is a flat ring fixed around a pipe where it passes through a concrete wall or slab. Cast into the concrete, it stops water tracking along the outside of the pipe.
Where should the puddle plate sit in the wall?
At the centre of the wall or slab thickness, unless the engineer's detail shows otherwise.
Which sizes do you make?
DN25 to DN1200, which is 1 inch to 48 inch nominal pipe size. Larger sizes and special plates are made to drawing.
Which materials are available?
Hot-dip galvanized carbon steel, mild steel black or primed, stainless steel 304L and 316L, and epoxy coated carbon steel.
How long should a puddle pipe be?
Wall thickness plus the projection needed on each side to make the connection. 150 mm each side is a common starting point for plain ends.
Get a quotation
Send your sizes. We reply with a price and a drawing.
Send a photo of your BOQ or drawing on WhatsApp, or build your items in the product selector.

- Telephone
- +974 4472 6271
- Qatar office
- Building 3, Street 400, Zone 56, Office 5, Salwa Road, Doha, Qatar
- Company
- A division of Aamtron Group
Aamtron Group General Contracting W.L.L.