Guide
Puddle flange installation: step by step
How to position, support and cast in a puddle flange so the penetration stays watertight.
A puddle flange only works if concrete fully surrounds the plate. Installation is simple, but it must be done before the pour.
Steps
- Check the item. Confirm pipe size, length, end type and plate position against the drawing. The plate should sit at the centre of the wall thickness.
- Cut the formwork. Make a neat hole in the shutter for the pipe so grout does not leak around it.
- Set level and line. Position the pipe to the required invert level and square to the wall. For flanged ends, set the bolt holes off-centre unless the drawing says otherwise.
- Tie it in. Fix the puddle pipe to the reinforcement with tie wire or welded bars so it cannot move during the pour. Do not cut main bars without the engineer's approval; trim bars are usually added around large openings.
- Protect the ends. Cap open ends and cover flange faces and threads.
- Pour and vibrate. Place concrete evenly on both sides of the pipe and vibrate under and around the plate so no voids remain.
- Strike and inspect. After the formwork is removed, check for honeycombing around the pipe and repair as the engineer directs.
- Test. The penetration is proved during the tank or basement water test.
Common mistakes
- Plate not centred in the wall
- Pipe not tied, so it moves during vibration
- Poor compaction under large pipes
- Wrong projection, leaving no room to connect
This is general guidance. The project specification and the engineer's instructions take priority.